200
7-55
7-56
7-43
7-57
8
Operation
Reading of error code E9
If E9 is read out, at least one error was made with
respect to the sequence of operations when performing
optimisation (System messages
F
7.1).
—
Abort the optimisation program by pressing the
STOP
key and, if desired, start optimisation once
again.
Fig. 7-55
MINIMISATION “9”
—
Clamp the wheel on the balancer.
—
Rotate the wheel such that the valve is exactly
perpendicular to and above the main shaft.
—
Confi rm the valve position by pressing key
8
.
The MINIMISATION “10” screen (
Fig. 7-56
) is
displayed.
Figura 7-56
MINIMISATION “10”
START is displayed on the screen.
—
Spinn the wheel.
A measuring run is performed.
The BALANCING screen (
Fig. 7-43
) is displayed.
Finish weight Minimisation
Fig. 7-43 BALANCING
—
Balance the wheel according to the readings.
If the wheel quiet running conditions cannot be
improved on, the following message is displayed:
Fig. 7-57
H0
Wheel running conditions cannot be improved by
optimisation.
..
_
..........