IPE300 series engineering VFD
Basic operation guidelines
-65-
Function
code
Name
Description
Default
2:
PROFIBUS/CANopen/DeviceNet
communication
3: Ethernet communication
4: EtherCAT/Profinet communication
Tens place: indicates whether to enable
switchover during running
0: Disable
1: Enable
Type of motor 2
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
Rated power of AM 2
0.1
–3000.0kW
Model
depended
Rated frequency of AM 2 0.01Hz
(Max. output frequency)
50.00Hz
Rated speed of AM 2
1
–36000rpm
Model
depended
Rated voltage of AM 2 0
–1200V
Model
depended
Rated current of AM 2 0.8
–6000.0A
Model
depended
Stator resistance of AM 2 0.001
–65.535Ω
Model
depended
Rotor resistance of AM 2 0.001
–65.535Ω
Model
depended
Leakage inductance of
AM 2
0.1
–6553.5mH
Model
depended
Mutual inductance of AM
2
0.1
–6553.5mH
Model
depended
No-load current of AM 2 0.1
–6553.5A
Model
depended
Rated power of SM 2 0.1
–3000.0kW
Model
depended
Rated frequency of SM 2 0.01Hz
50.00Hz
Number of pole pairs of
SM 2
1
–50
2