IPE300 series engineering VFD
Function parameter list
-227-
Function
code
Name
Description
Default Modify
control.)
1: Master/slave mode 1
(The master and slave must be in the same type
of vector control mode. The master is
speed-controlled and the slave will be forced into
torque control mode.)
2: Master/slave mode 2
The
slave
switches
from
speed
mode
(master/slave
mode
0)
to
torque
mode
(master/slave mode 1) at a frequency point.
Tens place: Slave start command source
0: Master
1: Determined by
Hundreds place: Slave send/master receive data
0: Enable
1: Disable
P28.03 Slave speed gain
0.0
–200.0%
The function code is valid only when P28.00=2.
100.0%
○
P28.04 Slave torque gain
0.0
–200.0%
The function code is valid only when P28.00=2.
0.0
–500.0%
100.0%
○
P28.05
Frequency point
for switching
between speed
mode and torque
mode in
master/slave
mode 2
0.00
–10.00Hz
5.00Hz
○
P28.06 Number of slaves 0-15
1
◎
P28.07
Slave reference
speed filter time
0.000
–10.000s
0.010s
○
P28.08
Slave speed
offset
-50.00%50.00%
The function code is valid only when P28.00=2.
0.00%
◎
P28.09
Slave reference
torque filter time
0.000
–10.000s
0.010s
○
P28.10
Slave torque
offset
-50.0%50.0%
The function code is valid only when P28.00=2.
0.0%
◎