IPE300 series engineering VFD
Function parameter list
-217-
Function
code
Name
Description
Default Modify
P23.11
Speed-loop
differential gain
0.00
–10.00s
0.00s
○
P23.12
High-frequency
current-loop
proportional
coefficient
In
the
closed-loop
vector
control
mode
=3), when the frequency is lower than the
current-loop high-frequency switching threshold
), the current-loop PI parameters are
; and when the frequency is
higher than the current-loop high-frequency
switching
threshold,
the
current-loop
PI
parameters are
setting range: 0
–20000
setting range: 0
–20000
–100.0% (of the max.
frequency)
1000
○
P23.13
High-frequency
current-loop
integral
coefficient
1000
○
P23.14
Current-loop
high-frequency
switching
threshold
100.0%
○
P23.15
–P
23.19
Reserved
0
–65535
0
●
P24 group
––Encoder of motor 2
Function
code
Name
Description
Default Modify
P24.00
Encoder type
display
0: Incremental encoder
1: Resolver-type encoder
2: Sin/Cos encoder
3: Endat absolute encoder
0
●
P24.01
Encoder pulse
number
Number of pulses generated when the encoder
revolves for one circle.
Setting range: 0
–60000
1024
◎
P24.02
Encoder
direction
Ones place: AB direction
0: Forward
1: Reverse
Tens place: Z pulse direction (reserved)
0: Forward
1: Reverse
Hundreds: CD/UVW pole signal direction
0: Forward
1: Reverse
0x000
◎
P24.03
Detection time of
encoder offline
fault
Indicates the detection time of encoder offline
fault.
Setting range: 0.0
–10.0s
1.0s
○