IPE300 series engineering VFD
Function parameter list
-206-
Function
code
Name
Description
Default
Modify
If channel B is of low electric level, the edge
counts up; if channel B is of high electric level,
the edge counts down.
2: A is positive pulse
Channel A is positive pulse; channel B needs
no wiring
3: A/B dual-channel pulse; channel A pulse
edge counts up, channel B pulse edge counts
down
Tens place: Pulse direction
Bit0: Set pulse direction
0: Forward
1: Reverse
Bit1: Set pulse direction by running direction
0: Disable, and BIT0 is valid
1: Enable
Hundreds place: Frequency multiplication
selection for pulse +direction (reserved)
0: No frequency multiplication
1: Frequency multiplication
Thousands place: Pulse control selection
Bit0: Pulse filter selection
0: Inertia filter
1: Moving average filter
Bit1: Overspeed control
0: No control
1: Control
P21.02
APR gain 1
The two automatic position regulator (APR)
gains are switched based on the switching
mode set through
. When the spindle
orientation function is used, the gains are
switched automatically, regardless of the
running, and
locked state.
Setting range: 0.0
–400.0
20.0
○
P21.03
APR gain 2
30.0
○