IPE300 series engineering VFD
Function parameter list
-242-
Function
code
Name
Description
Default
Modify
P93.10
Lower limit of
PT1000
calibration
temperature
-20.0
–50.0°C
-20.0°C
○
P93.11
Upper limit of
PT1000
calibration digital
quantity
0
–4096
3800
○
P93.12
Lower limit of
PT1000
calibration digital
quantity
0
–4096
0
○
P93.13
PT100/PT1000
disconnection
detection
enabling
0x00
–0x11
Ones place: PT100 disconnection detection
0: Disable
1: Enable
Tens place: PT1000 disconnection detection
0: Disable
1: Enable
0x00
◎
P93.14
PT100 current
temperature
-50.0
–150.0°C
0.0°C
●
P93.15
PT100 current
digital volume
0
–4096
0
●
P93.16
PT1000 current
temperature
-50.0
–150.0°C
0.0°C
●
P93.17
PT1000 current
digital volume
0
–4096
0
●
P93.18
Warning display
0
–4
0: No warning
1: PT100 overtemp (A-Ot1)
2: PT1000 overtemp (A-Ot2)
3: PT100 disconnection (A-Pt1)
4: PT1000 disconnection (A-Pt2)
0
●
P93.19
Reserved
0
–65535
0
●
P93.20
Type of sensor
for AI/AO card to
detect motor
temperature
0: No inputs
1: PT100 input
2: PT1000 input
3: KTY84 input
0
○