Function parameter list
-210-
Function
code
Name
Description
Default
Modify
1: Electrical level signal
Bit 9: Position source
0: Set by
1: PROFIBUS/CANopen setting
Bit10
–11: Reserved
Bit 12: Positioning curve setting (Reserved)
0: Straight line
1: S curve
P21.17
Position set in
digital mode
Used to set the position for digital positioning.
Actual position=
0
–65535
0
○
P21.18
Positioning
speed setting
0: Set by
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDIA
5: High-speed pulse HDIB
0
○
P21.19
Positioning
speed set in
digital mode
0
–100.0% (of the max. frequency)
20.0%
○
P21.20
Positioning ACC
time
Used to set the ACC/DEC time in the
positioning process.
Positioning ACC time means the time needed if
the VFD speeds up from 0Hz to the max.
output frequency (
Positioning DEC time means the time needed if
the VFD speeds down from the max. output
frequency (
) to 0Hz.
setting range: 0.01
–300.00s
setting range: 0.01
–300.00s
3.00s
○
P21.21
Positioning DEC
time
3.00s
○
P21.22
Positioning
holding time
Used to se the holding time after the
destination position is reached.
Setting range: 0.000
–60.000s
0.100s
○
P21.23
Origin searching
speed
0.00
–50.00Hz
2.00Hz
○
P21.24
Origin bias
0
–65535
0
○