IPE300 series engineering VFD
Dimension drawings
-346-
W1
W2
D1
H1
H2
6- ø13.0
W2
Figure C-17 Wall-mounting drawing for the 660V 250
–355kW models
VFD model
Outer dimension (mm)
Installation dimension (mm) Hole diameter
(mm)
Fixing
screw
W1
H1
D1
W2
H2
250kW
–355kW 680
960
380
230
926
13
M12
C.5.2 Flange installation dimensions
W1
H1
D1
W2
H2
98.0
D2
W2
W3
W4
H4
H2
H3
Figure C-18 Flange installation diagram for 660V 22
–132kW models
VFD model
Outer dimension
(mm)
Installation dimension (mm)
Hole
diameter
(mm)
Fixing
screw
W1
H1
D1
W2
H2
D2
W3
H3
W4
H4
22kW
–45kW
270
555 325 130 540 167 261 516 65.5
17
7
M6
55kW
–132kW 325
680 363 200 661 182 317 626 58.5
23
9.5
M8
Содержание IPE300 Series
Страница 1: ...IPE300 Series Engineering VFD...
Страница 3: ......
Страница 35: ...IPE300 series engineering VFD Installation guidance 24 Figure 4 12 660V 22 45kW Figure 4 13 660V 55 132kW...
Страница 383: ...6 6 0 0 1 0 0 8 1 2 202106 V1 0...