IPE300 series engineering VFD
Function parameter list
-239-
Function
code
Name
Description
Default Modify
P91.50
Output voltage
filter time
0.000
–10.000s
Valid when “4: Output voltage (×1, V)” is selected
for P15 group Sent PZD channel.
0.010s
○
P91.51
Partial function
selection 1 of
received PZD
0x00
–0x11
Ones place: Auxiliary frequency overlay selection
0: Disable
1: Enable
Tens place: Auxiliary torque overlay selection
0: Disable
1: Enable (Enabled when P03.40 is disabled)
00
◎
P91.52
Partial function
selection 2 of
received PZD
0x000
–0x111
Ones place: DP running speed source
0: Run at set frequency
1: Run at set speed
Tens place: Drop rate setting at drop control
0: Keypad
1: DP communication
Hundreds place: Setting of the number of slaves
0: Keypad
1: DP communication
000
◎
P91.53
Zero speed
threshold
0.00
–10.00Hz
2.00Hz
○
P91.54
Zero speed
detection time
0.00
–10.00s
1.00s
○
P91.55
Detection time of
torque limit
reached
0.00
–10.00s
1.00s
○
P91.56
Max.
temperature
detection cycle
1
–60000h
6
◎
P91.57
AB upper
computer DP
communication
analysis
0: By PPO configuration
1: By AB configuration
0
○