Goodrive300-01 inverter for air compressor Function parameters
-66-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
detection level
inverter will output underload pre-alarm.
Setting range of P11.11: 0~P11.09
Setting range of P11.12: 0.1~3600.0s
P11.12
Underload
pre-alarm
detection time
1.0s
○
P11.13
Output terminal
action during fault
Select the action of fault output terminals during
undervoltage and automatic reset.
0x00~0x11
LED ones:
0: Action during undervoltage
1: No action during undervoltage
LED tens:
0: Action during the automatic reset
1: No action during the automatic reset
0x00
○
P11.14
Speed deviation
detection
0.0~50.0%
Set the speed deviation detection.
10.0%
○
P11.15
Speed deviation
detection time
Set the speed deviation detection time.
Setting range of P11.15: 0.0~10.0s
0.0s
○
P11.16
Automatic
frequency
decreasing at
voltage drop
0: Invalid
1: Valid; when the grid voltage drops to the rated
voltage, the inverter will decrease the frequency
automatically to ensure the rated output torque.
1
○
P12 Group Motor 2
P12.00
Motor type 2
0:Asynchronous motor
1:Synchronous motor
Note: Switch the current motor by the switching
channel of P08.31.
0
◎
P12.01
Rated power of
AM2
0.1~3000.0kW
Set the parameters of the
controlled asynchronous
motor.
To guarantee the control
performance, be sure to set
Depend
on model
◎
P12.02
Rated frequency
of AM2
0.01Hz~P00.03 (Max.
output frequency)
50.00Hz
◎
P12.03
Rated speed of 1~36000rpm
Depend
◎