Goodrive300-01 inverter for air compressor Function parameters
-31-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
source of REV
rotation in torque
control
6:MODBUS communication
7: Reserved
8: Reserved
9: Reserved
Note: Setting mode 1~9, 100% corresponds to
the maximum frequency.
P03.16
Keypad setting for
upper frequency
of FWD rotation in
torque control
This function is used to set the upper limit of the
frequency. P03.16 sets the value of P03.14; P03.17
sets the value of P03.15.
The setting range: 0.00 Hz~P00.03 (Max. output
frequency)
50.00 Hz
○
P03.17
Keypad setting for
upper frequency
of REV rotation in
torque control
50.00 Hz
○
P03.18
Upper
electromotion
torque
source
This function code is used to select the
electromotion and braking torque upper-limit source.
0: Keypad (P03.20 sets P03.18, P03.21 sets
P03.19)
1: AI1
2: AI2
3: AI3
4: Pulse frequency HDI
5:MODBUS communication
6: Reserved
7: Reserved
8: Reserved
Note: Setting mode 1~9, 100% corresponds to
three times of the motor current.
0
○
P03.19
Upper braking
torque
source
0
○
P03.20
Keypad setting of
electromotion
torque
The function code is used to set the limit of the
torque.
The setting range: 0.0~300.0% (motor rated current)
180.0%
○
P03.21
Keypad setting of
braking torque
180.0%
○
P03.22
Weakening
coefficient in
constant power
zone
The usage of motor in weakening control
0.3
○
P03.23
Lowest
weakening point
20%
○