Goodrive300-01 inverter for air compressor Function parameters
-23-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
When the set frequency is above the lower limit one
again and it lasts for the time set by P01.20, the
inverter will run automatically.
The setting range: 0.0~3600.0s (valid when
P01.19=2)
P01.21
Restart after
power off
This function can enable the inverter to start or not
after power off and then power on.
0: Disabled
1: Enabled; if the starting need is met, the inverter
will run automatically after waiting for the time
defined by P01.22.
0
○
P01.22
The waiting time
of restart after
power off
The function determines the waiting time before the
automatic running of the inverter after power off and
then power on.
The setting range: 0.0~3600.0s (valid when
P01.21=1)
1.0s
○
P01.23
Start delay time
The function determines the brake release after the
run command is given, and the inverter is in a
stand-by state and wait for the delay time set by
P01.23
The setting range: 0.0~60.0s
0.0s
○
P01.24
Delay time of stop
speed
The setting range: 0.0~100.0 s
0.0s
○
P01.25
0Hz output
selection
Select the output mode at 0Hz.
0: Output without voltage
0
○