Goodrive300-01 inverter for air compressor Function parameters
-51-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
P07.30
Previous 3 fault
type
5: OC2
6: OC3
7: OV1
8: OV2
9: OV3
10: UV
11: Motor overload (OL1)
12: Inverter overload (OL2)
13: Input side phase loss (SPI)
14: Output side phase loss (SPO)
15: Overheat of rectifier module (OH1)
16: Overheat fault of inverter module (OH2)
17: External fault (EF)
18: 485 communication fault (CE)
19: Current detection fault (ItE)
20: Motor antotuning fault (tE)
21: EEPROM operation fault (EEP)
22: PID response offline fault (PIDE)
23: Braking unit fault (bCE)
24: Running time arrival (END)
25: Electrical overload (OL3)
26: Panel communication fault (PCE)
27: Parameter uploading fault (UPE)
28: Parameter downloading fault (DNE)
29~31: Reserved
32: Grounding short circuit fault 1 (ETH1)
33: Grounding short circuit fault 2 (ETH2)
34: Speed deviation fault (dEu)
35: Maladjustment (STo)
36: Underload fault (LL)
●
P07.31
Previous 4 fault
type
●
P07.32
Previous 5 fault
type
●
P07.33 Running frequency at current fault
0.00Hz
●
P07.34 Ramp reference frequency at current fault
0.00Hz
●
P07.35 Output voltage at current fault
0V
●
P07.36 Output current at current fault
0.0A
●
P07.37 Bus voltage at current fault
0.0V
●
P07.38 Max. temperature at current fault
0.0°C
●
P07.39 Input terminals state at current fault
0
●