Goodrive300-01 inverter for air compressor Function parameters
-34-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
torque boost is invalid.
The setting range of P04.01: 0.0%: (automatic)
0.1%~10.0%
The setting range of P04.02: 0.0%~50.0%
P04.03
V/F
frequency 1 of
motor 1
When P04.00 =1, the user can set V/F curve through
P04.03~P04.08.
V/F is generally set according to the load of the
motor.
Note:V1
<
V2
<
V3,f1
<
f2
<
f3. Too high low
frequency voltage will cause overheat or even
burnout of the motor and overcurrent stall or
protection of the inverter.
The setting range of P04.03: 0.00Hz~P04.05
The setting range of P04.04: 0.0%~110.0% (the
rated voltage of motor 1)
The setting range of P04.05: P04.03~ P04.07
The setting range of P04.06: 0.0%~110.0% (the
rated voltage of motor 1)
The setting range of P04.07: P04.05~ P02.02 (the
rated frequency of motor 1) or P04.05~ P02.16 (the
rated frequency of motor 1)
The setting range of P04.08: 0.0%~110.0% (the
rated voltage of motor 1)
0.00Hz
○
P04.04
V/F
voltage 1 of motor
1
00.0%
○
P04.05
V/F
frequency 2 of
motor 1
00.00Hz
○
P04.06
V/F
voltage 2 of motor
1
00.0%
○
P04.07
V/F
frequency 3 of
motor 1
00.00Hz
○
P04.08
V/F
voltage 3 of motor
1
00.0%
○
P04.09
V/F slip
This function code is used to compensate the 100.0%
○