Goodrive300-01 inverter for air compressor Function parameters
-21-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
The setting range of P01.09: 0.00Hz~P00.03 (Max.
output frequency)
The setting range of P01.10: 0.00~50.00s
The setting range of P01.11: 0.0~100.0%
The setting range of P01.12: 0.00~50.00s
P01.13
Dead time of
FWD/REV
rotation
During the procedure of switching FWD/REV
rotation, set the threshold by P01.14, which is shown
as the table below:
The setting range: 0.0~3600.0s
0.0s
○
P01.14
Shifting between
FWD/REV
rotation
Set the threshold point of the inverter:
0:Switch after zero frequency
1:Switch after the starting frequency
2: Switch after the speed reaches P01.15 and delays
for P01.24
0
◎
P01.15
Stop speed
0.00~100.00Hz
0.50Hz
◎
P01.16
Detection of
stopping speed
0: Detect according to speed setting (no stopping
delay)
1: Detect according to speed feedback (only valid for
vector control)
1
◎
P01.17
Detection time of
feedback speed
If set P01.16 to 1, the feedback frequency is less
than or equal to P01.15 and detect in the set time of
P01.17, the inverter will stop; otherwise the inverter
will stop after the set time of P01.17.
0.50s
◎