Goodrive300-01 inverter for air compressor Function parameters
-81-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
alarm, 0: normal
BIT12: pressure signal, 1: pressure signal fault, 0:
normal
BIT13: temperature signal, 1: temperature signal
fault, 0: normal
BIT14: low temperature protection, 1: low
temperature alarm, 0: normal
BIT15: master state, 1: run, 0: stop
P19.14
Signal state 2
BIT0: tip for maintenance of component 1, 1: need
maintenance, 0: normal
BIT1: tip for maintenance of component 2, 1: need
maintenance, 0: normal
BIT2: tip for maintenance of component 3, 1: need
maintenance, 0: normal
BIT3: tip for maintenance of component 4, 1: need
maintenance, 0: normal
BIT4: tip for maintenance of component 5, 1: need
maintenance, 0: normal
BIT11: Maintenance overtime reminder, 1:
Maintenance overtime reminder, 0: Normal
BIT13: Low exhaust pressure reminder, 1: Low
pressure pre-alarm, 0: Normal
0
●
P19.15
Device state
0: Stand-by
1: Run
2: Fault
3: Emergency stop
4: Undervoltage
5: Alarm
6: Hibernation
7: Stop
8: Restart delay
0
●
P19.16
Accumulative
running time
0~65535h
0
●
P19.17
Accumulative
running time for
loading
0~65535h
0
●
P19.18 Restart countdown 0~3600s
0s
●
P19.19
PID temperature
output
0.00~100.00%
0.00%
●