Goodrive300-01 inverter for air compressor Function parameters
-16-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
1: A frequency command
100% of B frequency setting corresponds to the
maximum output frequency. Select this setting if it
needs to adjust on the base of A frequency
command.
P00.09
Combination of
the setting source
0: A, the current frequency setting is A frequency
command
1: B, the current frequency setting is B frequency
command
2: A+B, the current frequency setting is A frequency
c B frequency command
3: A-B, the current frequency setting is A frequency
command - B frequency command
4: Max (A, B): The bigger one between A frequency
command and B frequency is the set frequency.
5: Min (A, B): The lower one between A frequency
command and B frequency is the set frequency.
Note: The combination manner can be shifted by
P5 (terminal function).
0
○
P00.10
Keypad setting
frequency
When A and B frequency commands are selected as
“Keypad setting”, the value of the function code is
the original setting one of the frequency data of the
inverter.
The setting range: 0.00 Hz~P00.03 (Max. output
frequency)
50.00Hz
○
P00.11
ACC time 1
ACC time means the time needed if the inverter
speeds up from 0Hz to the Max. one (P00.03).
DEC time means the time needed if the inverter
speeds down from the Max. output frequency
(P00.03) to 0Hz.
Goodrive300-01 series inverters define four groups
of ACC/DEC time which can be selected by P05.
The factory default ACC/DEC time of the inverter is
the first group.
The setting range of P00.11 and P00.12:
0.0~3600.0s
Depend
on model
○
P00.12
DEC time 1
Depend
on model
○
P00.13 Running direction
0: Runs at the default direction, the inverter runs in
the forward direction. FWD/REV indicator is off.
1: Runs at the reverse direction, the inverter runs in
2
○