Goodrive300-01 inverter for air compressor Function parameters
-52-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
P07.40 Output terminals state at current fault
0
●
P07.41 Running frequency at previous fault
0.00Hz
●
P07.42 Ramp reference frequency at previous fault
0.00Hz
●
P07.43 Output voltage at previous fault
0V
●
P07.44 Output current at previous fault
0.0A
●
P07.45 Bus voltage at previous fault
0.0V
●
P07.46 Max. temperature at previous fault
0.0°C
●
P07.47 Input terminals state at previous fault
0
●
P07.48 Output terminals state at previous fault
0
●
P07.49 Running frequency at previous 2 fault
0.00Hz
●
P07.50 Ramp reference frequency at previous 2 fault
0.00Hz
●
P07.51 Output voltage at previous 2 faults
0V
●
P07.52 Output current at previous 2 faults
0.0A
●
P07.53 Bus voltage at previous 2 fault
0.0V
●
P07.54 Max. temperature at previous 2 fault
0.0°C
●
P07.55 Input terminals state at previous 2 fault
0
●
P07.56 Output terminals state at previous 2 fault
0
●
P08 Group Enhanced function
P08.00
ACC time 2
See P00.11 and P00.12 for detailed definition.
Goodrive300-01 series define four groups of
ACC/DEC time which can be selected by P5 group.
The first group of ACC/DEC time is the factory
default one.
The setting range: 0.0~3600.0s
Depend
on model
○
P08.01
DEC time 2
Depend
on model
○
P08.02
ACC time 3
Depend
on model
○
P08.03
DEC time 3
Depend
on model
○
P08.04
ACC time 4
Depend
on model
○
P08.05
DEC time 4
Depend
on model
○
P08.06
Jogging
frequency
This parameter is used to define the reference
frequency during jogging.
Setting range: 0.00Hz ~P00.03 (Max. output
frequency)
5.00Hz
○
P08.07 Jogging ACC time
The jogging ACC time means the time needed if the
inverter runs from 0Hz to P0.03.
The jogging DEC time means the time needed if the
Depend
on model
○
P08.08 Jogging DEC time
Depend
○