GD200A series VFD
Function parameters
-91-
Function
code
Name
Description
Default
value
Modify
1: Overload integral is valid
Setting range: 0000
–1131
P11.11
Detection level
of underload
pre-alarm
If the VFD current or the output current is lower
than
, and its lasting time is beyond
, the VFD will output underload pre-alarm.
Setting range of
: 0
Setting range of
: 0.1
–3600.0s
50%
○
P11.12
Detection time
of underload
pre-alarm
1.0s
○
P11.13
Output terminal
action during
fault
Select the action of fault output terminals on
undervoltage and fault reset.
0x00
–0x11
LED ones:
0: Action under fault undervoltage
1: No action under fault undervoltage
LED tens:
0: Action during the automatic reset
1: No action during the automatic reset
0x00
○
P11.16
Extension
functions
selection
0x00
–0x11
LED ones: Voltage drop frequency-decreasing
selection
0: Voltage drop frequency-decreasing selection
disable
1: Voltage drop frequency-decreasing selection
enable
LED tens: Step 2 ACC/DEC time option
0: Step 2 ACC/DEC time option disable
1: Step 2 ACC/DEC time option enable
,
when
running frequency more than
, ACC/DEC
time switch to step 2 ACC/DEC time
00
○
P13 Group Enhanced function parameters
Function
code
Name
Description
Default
value
Modify
P13.13
Braking current
of short-circuit
When
=0 during the starting of the VFD, set
to a non-zero value to enter the short
circuit braking.
When the running frequency is lower than
during the stopping of the VFD, set
to a
non-zero value to enter into stopping short
circuited braking and then carry out the DC
braking at the time set by
(refer to the
instruction of
0.0%
○
P13.14
Braking
retention time
before starting
0.00s
○
P13.15
Braking
retention time
when stopping
0.00s
○