GD200A series VFD
Function parameters
-75-
Function
code
Name
Description
Default
value
Modify
time from the highest point to the lowest one.
Setting range of
: 0.0
–100.0%
(relative to the set frequency)
Setting range of
: 0.0
–50.0%
(relative to the traverse range)
Setting range of
: 0.1
–3600.0s
Setting range of
: 0.1
–3600.0s
P08.19
Number of the
displayed
decimal points
Ones: Number of decimal points of linear speed
0: No decimal point
1: One decimal point
2: Two decimal points
3: Three decimal points
Tens: Number of decimal points of frequency
0: Two decimal points
1: One decimal point
Range: 0x00
–0x13
0x00
○
P08.20
Correcting
analog input
and output
0: Correct
1: Not correct
Setting range: 0
–1
0
◎
P08.25
Setting
counting value
The counter counts the input pulse signals through
the S terminals (with the counter triggering
function) or HDI (P05.00=1).
When the counter achieves a fixed number, the
multi-function output terminals will output the
signal of "fixed counting number arrival" and the
counter go on working; when the counter achieves
a setting number, the multi-function output
terminals will output the signal of "setting counting
number arrival", the counter will clear all numbers
and stop to recount before the next pulse.
The setting counting value
more than the setting counting value
The function is illustrated as below:
S terminal/HDI
HDO, RO1, RO2
HDO, RO1, RO2
The set
count value
is reached.
The specified
count value
is reached.
Setting range of
–65535
Setting range of
: 0
0
○
P08.26
Reference
counting value
0
○