INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
124/196
Main function
Sub function/
Direction/
Floor
Floor
Doors
Description
Emerg. run
-
-
Emergency run (landing calls off - only car calls active)
More settings see „Special param." – "Emerg. run adj.“
Hazard run
-
-
Hazardous good transportation function
More settings see„Special param." – "Hazard transport"
Lift off
-
-
Switching off the lift in current / next floor
Lift off disp
-
-
Input for activating the "Out of order" display (e.g. for maintenance activities)
Door op.push
Floor (only
if set on ESE
input)
Doors
Door open push
More settings see „Door parameter – Gener.door para.“
Door cl.push
Floor (only
if set on ESE
input)
Doors
Door close push
More settings see „Door parameter – Gener.door para.“
Dr.stop push
Floor (only
if set on ESE
input)
Doors
Door stop push (for keep door open e.g. for loading / unloading)
Presence.sen.. Floor (only
if set on ESE
input)
Doors
Anteroom surveillance to extend the door open time
(if passengers are waiting for the lift)
Clear calls
-
-
Push input to clear all calls
LC off
-
-
Disable all landing calls
Remote off
Floor
Doors
Remote switch off lift
First lift goes to the floor programmed with this input and opens the door.
Second the lift goes to the floor programmed in „Special param. – Remote off“
and goes out of operation.
Interm.door
-
-
Switch on intermediate door.
If intermediate door is open the lift may only be used in special run mode (key
switch) or any other special control with higher priority (VIP run, ...)
Clock run 1
-
-
Input to start clock runs.
More settings see „Special param." – "Clock run" and also "Door releases"
Note: The clock run 1 may be activated by this input as well as by the internal
timer (see „Special param." – "Clock run“)