INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
6/196
LSI
Lower Signaler
see SGU; Designation is used only when using
the main board MCU
MCU
Main Control Unit
Main assembly of the controller; usually installed
in the control cabinet
MS3-C
Car position indicator 2 arrow (dot matrix
5 * 7) with CAN-Bus connection and 7 inputs /
outputs (can be used in the cabin or outside the
panel). Not used for new installations
MSI
Middle Signaler
see SGM; Designation is used only when using
the main board MCU
PCU
Panel Control Unit
see TSE; Designation is used only when using the
main board MCU
PMA
Punktmatrixanzeige
Car position indicator 2 arrow (dot matrix
5 * 7) with CAN-Bus connection and 8 inputs /
outputs (can be used in the cabin or outside the
panel)
PSE
Positionssteuereinheit
Positioning (adapter assembly between
incremental and CAN bus)
RSI
Reference Signaler
see SGE; Designation is used only when using
the main board MCU
SDS
Slow Down Switch
see SGV; Designation is used only when using
the main board MCU
SGE
Signalgeber zum Eichen
Reference or calibration switch SGE; is used as
reference point for the positionin
SGM
Signalgeber mitte
Center door zone switch (also leveling switch,
usually bistable magnetic switches, inductive or
capacitive switches)
SGO
Signalgeber oben
upper door zone switch (usually bistable
magnetic switches, inductive or capacitive
switches)
SGU
Signalgeber unten
lower door zone switch (usually bistable magnetic
switches, inductive or capacitive switches)
SGV
Signalgeber Verzögern
Slow down switch to switch to levelling speed if
arriving the target floor
SRU
Safety Relais Unit
Safety assembly for advanced door opening and