![Intec MLC 8000 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/intec/mlc-8000/mlc-8000_operating-manual_2070494037.webp)
INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
37/196
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Description
no).
If set to "yes" emergency trips have higher priority than fire alarm
control (see below)
Run to fire
Indicates whether the floors can be reached in which a fire alarm is
active (yes / no)
Parking trip
Parameters for park ride
Park mode
Fixed: The lift goes to a fixed Park Floor
Zones: The lift is parked in the pre-defined zones (mainly for lift
groups)
Park floor
Park floor if park mode is "Fixed"
(Note: Up to version 1.32y this parameters is displayed in the menu
"General parameter")
Parktime[s]
If the lift is not used for this time the lift will go to the specified parking
level.
(Note: Up to version 1.32y this parameters is displayed in the menu
"Timer parameter")
Zone 1 Start
Bottom floor of the parking zone 1
Zone 1 Stop
Top floor of the parking zone 1
Note: If the top floor value is less than the bottom floor value, then the
parking zone is disabled
Zone 2 Start
See above
Zone 2 Stop
See above
....
Zone 8 Start
See above
Zone 8 Stop
See abov
Mand.zones
Specifies how many parking zones (starting with zone 1) must be
filled.
Example: In a group lift 1 is parked within zone 1 and lift 2 is parked in
zone 2. If lift 1 is called to another floor and the value of "Mandatory
zones" is> 0, then lift 2 goes to zone 1 and parks there. If the value
"Mandatory Zone = 0 he would remain in Zone 2.
Visitor calls
Parameters for visitors calls and visitor control
CC enabl.[s]
Time period car calls are enabled after the lift was sent to a floor by a
visitor call (type 1 and type 2)