INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
24V
+24V Power supply input
0V
0V Power supply input
FB
Feedback output "Door zone bypass active"
Technical specifications:
Dimension (LxWxH) mm:
100 x 22 x 114
Housing protection class:
IP50, Connectors: IP 20
Operating temperature:
-25 C to + 65 * C
Attachement:
DIN rail according to EN 50022 and EN 50035
Connection size:
max. 4 mm²
Power supply:
24 V DC + 10% / - 15% (Connectors 24V and 0V)
Main signal output
max. 230V AC / 4 A (Connectors S1 and S2)
Feedback output:
24 V DC low active, max. 1 A (terminal FB)
Nominal values:
according to EN81-1, Appendix F1.2: 230V AC, 2A
EMC:
according to requirements of EN 12015 and EN 12016
Characteristics and features:
-
Safety unit for bypassing safety circuit of doors inside door zone (for re-levelling and advanced
door opening)
-
dual-channel version
-
for use with main board MCU of lift controller MLC-8000
-
TÜV certified
-
for more details refer to TÜV certificat ESD 058-2008-CHI
Appendix 1.11 Module LCD-047
Rückseite
XL1
XL2
XL3
XL4
XL6
XLJ1
XLJ2
K1
K2
K3
LED
PIN1
PIN1
PIN1