Lift controller MLC 8000
Operating manual V2.0
147/196
Main function
Sub function/
Direction/
Floor
Floor
Doors
Description
-Bear.bot.Warn
in.
Car apron
-
-
Output for electrical locking of folding car apron.
Governor
Dir.
-
Output to activate a descent stopping system (e.g. coil on
overspeed governor, emergency stopping valve, A3 device, ….)
Uncontr.Mov
-
-
Output uncontrolled movement (UCM) detected.
Used to switch off safety circuit.
Hold.bolt
- Bolt out
- Bolt in
-
-
Output to pull in / pull out holding bolts.
- Bolt is out
- Bolt is in
Signal no.
-
Output for signaling "Holding bolt x is pulled out"
OP device
- Out
- In
-
-
Output to pull in / pull out the load derrick of a hospital operation
lift mit automatic loading / unloading.
- Right
- Left
-
-
Output to move the rotary table of a hospital operation lift mit
automatic loading / unloading.
Ramp
-
-
Output to switch the load interlock of a hospital operation lift mit
automatic loading / unloading.
Conn.IO
- "--"
- on delay
- off delay
- on+off
- Pulse
- Bistable
Signal no.
Delay[s]
See description of input function.
Additionally it may be defined for each single output
- on delay
- off delay
- on and off delay
- Pulse
The delay or pulse wide may be programmed with "Delay[s]".
By using the "Bistable" function the state of the output is toggled
always if the connected input is switched on.