INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
142/196
Main function
Sub function/
Direction/
Floor
Floor
Doors
Description
Vis.request
Callfloor
-
Doors
Acknowledgement output for visitor request..
For more detailled description refer to "Special param. - Visitor
floors" in chapter "menu structure"
Hazard.call
Floor
Doors
Hazard call acknowledgement(see input functions)
Level displ.
Type:
- 1 of n
- Binary
- Graycode
- 7-Segm.
- 9-Seg.K
Signal no.
Offset
Outputs for controlling a conventional car level indicator (1-of-n-
coded, binary coded or Gray code). With 1-of-n setting the output is
set according to the setting "Signal no" in each floor.
For binary or gray code the signal number corresponds to the
relevant binary digit within the binary or Gray code.
Via the parameter "Offset" it can be selected, which binary or Gray
code value is output in which floor. When set to '1' the binary or
Gray code value 1 is set in the 1st floor, in floor 2 the value 2, etc.
When set to '0' the binary or Gray code value 0 is set in the 1st floor
(that means all outputs off), etc.
The assignment of the "Signal no." for a 7- or 9-segment display is
shown in the picture. For this type of displays it can be adjusted via
the "offset" if the units digit (= 1) or ten's digit (= 2) is to be
controlled.
Hall lantern
Dir.
Floor
Doors
The hall lantern output is used for signaling that the lift reaches a
floor. The signal is activated if the lift slows down for arrival.
Always the direction of the next handled call is displayed. The
signal is deactivated if the doors are closed again.
If no further call exists the hall lanterns for both directions are
displayed.
The settings "Dir.", "Floor" and "Doors" can be omitted optional;
then the output is valid for all directions / Floors / Doors.
Dir.arrow
Dir.
-
-
If the lift is moving the direction arrow for the travel direction is set,
while in standstill the direction to the next call is displayed.
While moving the arrows light up continuously; in standstill state
the arrows are flashing every second.
Mov.arrow
Dir.
Moving arrows always show the actual travel direction.
Gong
Dir.
Floor
Doors
Output to control a gong.
More settings see „Special param.“ - „Gong“
Speech
Direction up
-
-
Signal for speech unit for next travel direction upwards (set by