![Intec MLC 8000 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/intec/mlc-8000/mlc-8000_operating-manual_2070494048.webp)
INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
48/196
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Description
LC config.2
Enabled doors and floors for landing calls if call configuration 2 is
active
1. Floor
Enabled doors in floor 1
2. Floor
Enabled doors in floor 2
...
CC config.2
Enabled doors and floors for car calls if call configuration 2 is active
1. Floor
Enabled doors in floor 1
2. Floor
Enabled doors in floor 2
...
LC-config.3
Enabled doors and floors for landing calls if call configuration 3 is
active
...
...
En/Disable calls
Parameters for enabling / disabling doors and floors
Disable
normal: When an input is activated for disabling of calls or doors, then
only "normal" calls are affected
+special: Through an active input for disabling of doors or calls both
"normal" calls and special calls are affected
Enable
normal: When an input is activated for enabling of calls or doors, then
only "normal" calls are affected
+special: Through an active input for enabling of doors or calls both
"normal" calls and special calls are affected
Autom.CC
yes: If an input is activated to enable a car call for a floor or door, then
a car call for the appropriate floor and door is automatically set in this
moment.
Autom.LC
yes: If an input is activated to enable a landing call for a floor or door,
then this landing call is automatically set in this moment.
Clear Call
yes: When setting an input for disabling a car call, an already existing
car call for this floor is cleared.
Priority
Disable: If for one call, at the same time, an input was given to enable
this call and an input to disable this call, then the disable input has
priority .
Enable: If for one call, at the same time, an input was given to enable
this call and an input to disable this call, then the enable input has