INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
133/196
Main function
Sub function/
Direction/
Floor
Floor
Doors
Description
- Bolt in
With setting of "Signal no." up to 4 independend switches may be connected to
the lift controller.
Holded
-
-
Signal that lift is in holding position.
- Test on
- Test in
- Test out
- Test Stop
- Test up
- Test down
-
-
Control signals to check the functionality of the holding device.
- Test on:Activate test mode
- Test in: Move holding device in
- Test out: Move holding device of
- Test Stop: Stops all movement of holding device immediately
- Test up: Moves lift upwards with speed vAh
- Test down: Moves lift downwards with speed vAs
OP device
- Out
- In
-
-
Limit switch on load derrick of a hospital operation lift mit automatic loading /
unloading.
Right
-
-
Contact on rotary table of a hospital operation lift mit automatic loading /
unloading.
Ramp
-
-
Contac on load interlock of a hospital operation lift mit automatic loading /
unloading.
Slick test
-
-
Pulse count input for slick monitoring (2. position sensor on car; sometimes
necessary on lifts without machine room).
Brake/valve
- Brake 1
- Brake 2
- Brake 3
-
-
Supervision input for motor brake
Brake warning
-
-
Warning contact for wear of motor brake
- Up valve
- Down valve 1
- Down valve 2
- Emerg.valve
-
-
Supervision contact for hydraulic valves
Pressure
- Minpressure
- Maxpressure
-
-
Hydraulic pressure signal
Note: Not the same function like overload input!
Temp.
- Overtemp.1
- Overtemp.2
-
-
Temperature sensor, mainly used for motor or oil temperature supervision.