UEA.2 Hardware-Version 2.0
UEA.1 Hardware-Version 2.0
Position
Pin
Function
XU1
1
+24V
+24V Power supply input
2
0(24V)
0V Power supply input
3
CAN+
CAN-Bus – High signal
4
CAN-
CAN-Bus – Low signal
XU2
1
0(24V)
0V Power supply for inputs / outputs
2
3
4
5
6
7
8
9
D1
D2
D3
D4
D5
D6
D7
D8
8 inputs / outputs E1-E8 and A1-A8, low active (UEA.1) or high active
(UEA.2), free programmable.
Connector XU2 is in parallel to XU3 (same inputs/outputs)
10
+24V
+24V Power supply for inputs / outputs
XU3
1
2
3
4
5
6
7
8
D1
D2
D3
D4
D5
D6
D7
D8
8 inputs / outputs E1-E8 and A1-A8, low active (UEA.1) or high active
(UEA.2), free programmable.
Connector XU3 is in parallel to XU2 (same inputs/outputs)
9
0(24V)
0V Power supply for inputs / outputs
10
+24V
+24V Power supply for inputs / outputs
XU4
Connector for plugging UEA on HSE, FVE or TVE
1
Pin1
Not used (closed to protect against incorrect connection)
2
+24V
+24V Power supply input
3
0(24V)
0V Power supply input
4
CAN+
CAN-Bus – High signal
5
CAN-
CAN-Bus – Low signal
6
Pin6
Not used (closed to protect against incorrect connection)
XU5
Connector for Software download
X
U2
X
U2
X
U1
X
U1
X
U3
XU
5
XU
5
XU4
XU4
XU6
XU6
XU7
XU7
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
Pin1
LED
LED
Pn2
Pn2