Position Terminal no.
Description
Function
4
EAF11
5
EAF12
6
EAF13
7
EAF14
8
EAF15
9
EAF16
10
+24A
Battery bu24V power supply, flat cable to TVE
11
+24V
+24V power supply, flat cable to TVE
12
GND
0V power supply, flat cable to TVE
13
+24V
+24V power supply, flat cable to TVE
14
NL
Emergency light car operation panel COP (Output A7), flat cable to TVE
15
+24A
Battery bu24V power supply, flat cable to TVE
16
M
Intercom microphone, flat cable to TVE
17
L
Intercom loudspeaker, flat cable to TVE
18
CH+
Control bus (CAN Bus 1) – High signal, flat cable to TVE
19
CH-
Control bus (CAN Bus 1) – Low signal, flat cable to TVE
20
GND
0V power supply, flat cable to TVE
XF21
Connector for Software download
XF22
Modul 1
Slot 1 for connecting a UEA to power supply and CAN bus
For configuration see description of Jumper XFJ1
XF23
Modul 2
Slot 1 for connecting a UEA to power supply and CAN bus
For configuration see description of Jumper XFJ2
LED
LED “Software is running”
Technical specifications:
Temperature range:
0
°
C to +60
°
C
Max. power consumption by 24V:
<
200mA @ 25
°
C (all relays and in-/outputs active)
Max. input current 24V inputs:
10mA @ 25
°
C / Input
Max. current KF1 to KF7:
8A/250V AC / Relay
Max. output current A9-16
500mA @ 25
°
C / Output
Max. input current 230V DC input(car light):
10mA @ 25
°
C, 230VAC, 50Hz
Mechanical dimensions:
Length:
230mm
Width:
135mm
Height:
ca. 40mm
Characteristics and features:
The module FVE is designed as an intelligent distribution board for use on the car roof or in the car
operation panel COP. However, in opposite to FVE version 1.1 and 2.1, there are no connectors for
safety circuit, earth connection, power supply etc. onboard.
- PIC18-Microcontroller with integrated Flash memory (32kByte), RAM (1536 Byte) and EEPROM
(256 Byte)
- integrated CAN bus controller
- CAN interface with high speed driver according to ISO11898 with galvanic isolation