INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
136/196
Main function
Sub function/
Direction/
Floor
Floor
Doors
Description
Special run
-
-
Output is activated if lift controller is in Special trip mode
VIP run
-
-
Output is activated if lift controller is in VIP trip mode
Emerg. run
-
-
Output is activated if lift controller is in Emergency trip mode
Out of work
-
-
“Out of work” indicator; output is activated if:
- Error state
- Doors disabled
- Maintenance count has reached its limit (see menu item
„Statistics“ –> „Maint.count“ and parameter „Maint.interval“
- Car calls disabled
- Landing calls disabled (only if output is programmed on an ESE
board on the shaft bus)
Additional this output is activated during normal operation:
- by settingin menu item „Test“ -> „Out of work“
- by input function „Special func.“ -> „Out of work“ (see input
functions above)
Inspection
-
-
Output is activated in inspection mode (top of car or shaft pit)
Inspect.Car
-
-
Output is activated in inspection mode (top of car)
Inspect.Pit
-
-
Output is activated in inspection mode (shaft pit)
Ramp drive
-
-
Output is activated in ramp drive mode
Buzzer
Type:
-Load
-Door
-Load+Door
-Carcall
-Load+CC
-Door+CC
-Load+CC+Door
-
Depending on the setting "type" the buzzer may be used for
different functions:
- as overload buzzer
- while forced door closing (Light screen ignored)
- short acoustic signal (2s) if a car call is pressed
CC Buzzer
-
-
Car call buzzer; same function like above setting "Car call"
LC Buzzer
Floor
Doors
Landing call buzzer;short acoustic signal (2s) if landing call is
pressed.