INTEC GmbH
22/12/2016
Lift controller MLC 8000
Operating manual V2.0
135/196
7.7.2. Output functions
Main function
Sub function/
Direction/
Floor
Floor
Doors
Description
Land.call
Direction:
- Up
- Down
- Up+Dn
Call floor
Doors
Acknowledgement output of "normal" landing call; see input
functions
Land.call1
Direction:
- Up
- Down
- Up+Dn
Call floor
Doors
Acknowledgement output of landing call 1; see input functions
Land.call2
Direction:
- Up
- Down
- Up+Dn
Call floor
Doors
Acknowledgement output of landing call 1; see input functions
Special LC
Call floor
-
Doors
Acknowledgement output of special landing call; see input
functions
VIP LC
Call floor
-
Doors
Acknowledgement output of VIP landing call; see input functions
Emerg.LC
Call floor
-
Doors
Acknowledgement output of emergency landing call; see input
functions
Car call
Call floor
-
Doors
Acknowledgement output of car call; see input functions
Spec.out.
Car fan
-
-
Output for car fan
May be used as output to switch on the car fan as well as for
acknowledgement of car fan button.
More settings see „Special param.“ -> „Car fan“
Special mode
-
-
Output is activated if lift controller is in one of the special modes:
- Special trip / VIP trip / Emergency trip
- Lift switched off
- Landing calls disabled
- Clock run