68
IDS X-Series Training v2.7
Location 458 to 498: Output On / Off Days
Location Type: Bitmap
Each output can be scheduled to switch on or off on certain days of the week.
Manually Triggered
The outputs can be triggered via the keypad, by pressing and holding the [MODE] key until you hear a beep
(about 3 seconds) then pressing [3][*]. Enter the [output number] [*] (LCD keypad press [*]
again).
Follow the same procedure to turn the output off.
NOTE: X-Series systems version earlier than v2.50 could only manually trigger the panel’s onboard outputs
(1 to 5)
Event Reporting
When using Contact ID and SIA formats all event codes are programmed into the X-Series alarm system
and only need to be enabled or disabled in the following locations. The first eight options are to enable or
disable the reporting and the second 8 are to select which group of phone numbers to use.
Location 501 to 564 Global Split Reporting
Location Type: Bitmap
These locations are for each of the zones, 501 is for zone 1, 502 is for zone 2, 503 is for zone 3, etc.
LED Default
Action
Explanation
Split
Reporting
Option
Default
1
ON
Zone Alarm
Reporting
If this option is selected whenever a zone is
violated the alarm reports via telephone.
9
OFF
2
OFF
Zone Alarm Restore
When the zone restores the alarm reports via
telephone.
10
OFF
3
OFF
Zone Bypassing
When a zone is bypassed it is reported via
telephone.
11
OFF
4
OFF
Zone Force
Bypassing
When the system is set to bypass zones that
are violated when arming it reports that it was
forced to arm by bypassing zones.
12
OFF
5
OFF
Zone Tamper
When tamper has been set for a zone and the
tamper signal is received it will be reported via
telephone.
13
OFF
6
OFF
Zone Tamper
Restore
When the tamper restores a report is sent via
telephone.
14
OFF
7
OFF
Zone Swinger
Shutdown
A zone shuts down because it has exceeded
the shutdown count and the system will report
via telephone.
15
OFF
8
OFF
Zone Swinger
Shutdown Restore
At the auto test report, the system will try and
restore the zone if it is not violated and this will
be reported via telephone.
16
OFF
Option
ON Days
Option OFF Days
1
Monday
9
Monday
2
Tuesday
10
Tuesday
3
Wednesday
11
Wednesday
4
Thursday
12
Thursday
5
Friday
13
Friday
6
Saturday
14
Saturday
7
Sunday
15
Sunday
8
Disabled
16
Disabled