114
IDS X-Series Training v2.7
Action
Code
Command
Ext. Command
Data
Increase the reporting
threshold to 50 SMSes
1234
Report
Threshold
50 073 917 0759
Decrease the reporting
threshold to 14 SMSes
1234
Report
Threshold
14 071 348 9467
2.5.
Arm/Disarm
Master and Arming phone numbers are able to arm or disarm the X-Series Alarm Panel in multiple profiles.
Arming the panel requires a valid user code for the partition you want to arm/disarm.
To away arm partition 1 you will use the following information:
Code – 1234 (a valid user code in partition 1)
Command – Arm
Extended Command – *
Not needed
Data – P1 (Partition number)
The SMS should look like this:
1234 arm p1
To arm partition 3 in stay profile 2 you will use the following information:
Code – 1234 (a valid user code in partition 1)
Command – Arm
Extended Command – S2 (Stay Profile number)
Data – P3 (Partition number)
The SMS should look like this:
1234 arm s2 p3
All arm/disarm commands:
Action
Code
Command
Ext. Comm
Data
Away arm all partitions
1234
Arm
All
Away arm P1 & P3
1234
Arm
P1,P3
Stay arm P2 in stay profile 3
1234
Arm
S3
P2
Stay arm P1 & P4 in stay profile 1
1234
Arm
S1
P1,P4
Disarm all partitions
1234
Disarm
All
Disarm P2
1234
Disarm
P2
Disarm P5 & P6
1234
Disarm
P5,P6
2.6.
Bypass/Unbypass
When needed you are able to send a command to bypass or unbypass a specific zone/s. You must
specify which zones to bypass in the data field.
To bypass zone 3 you will use the following information:
Code – 1234 (a valid user code)
Command – Bypass
Extended Command – *
Not needed
Data – 3 (Zone number)