32
IDS X-Series Training v2.7
Location 17: Siren Time Out
Location Type: Standard
This is the time the siren will turn off after an alarm is registered.
Data format: mmss
Valid Range:
0001 - 5959
Default: 0200
Location 18: Siren Delay
Location Type: Standard
The siren can be delayed not to sound for a specific time after an alarm is registered. For the siren delay to
take effect location 14 sub-location 7 must be enabled.
Data format: mmss
Valid Range: 0001 - 5959
Default: 0200
Location19: Extra Global Options
Location Type: Bitmap
These options are global to the alarm system and affect all partitions.
LED Default
Action
Description
1*
OFF Wireless Zone Supervision Trigger
This option enables or disables wireless supervision failures
from triggering alarms. Supervision monitors the wireless
devices to make sure that they remain communicating with
the system.
2
OFF Voice Login Lockout
This option enabled the voice module to follow the keypad
lockout settings.
3
OFF 24Hour Zone Report Only
This option enables 24hour zones to only report when
triggered. No other actions on the panel will occur, siren won't
sound and the keypad will not show an alarm condition.
4
OFF Box tamper always triggers the siren
This option will trigger the siren when a box tamper is
triggered whether the system is armed or not.
5
OFF
Bus-wired peripheral tamper always
triggers the siren
This option will trigger the siren when a bus-wired peripheral
tamper is triggered whether the system is armed or not.
6
OFF Zone tamper always triggers the siren
This option will trigger the siren when a zone tamper is
triggered whether the system is armed or not.
7
OFF Voice Module Answers before modem
This option enables the voice module to answer calls to the
panel before the dialler answers.
*NB: This feature is only available when using wireless expanders v1.07 or higher
Location 20: Keypad Lockout Count
Location Type: Standard
If a user code is entered incorrectly the number of times entered in this location the keypad will lock-up for
the time entered in location 21.
Valid Range: 2 - 16
Default: 4
Note: Keypad lockout must be enabled under extra partition options.
(Location 221 to 228 option 4 depending on the partition the keypad belongs too.)