IDS X-Series Training v2.7 | Hardware
7
6.
X-Series Connectors
The above figure shows how the X-Series connectors are laid out. Each connection will be briefly discussed.
Please note that devices, especially between different manufacturers, may be different and their manuals
should be thoroughly read and understood before attempting installation.
6.1.
AC Power
The minimum transformer you can use is a 16V 32VA, but
the recommended transformer is a 16V 40VA transformer.
6.2.
TX
The TX connection can supply enough power for radios up to 15 watts.
NOTE:
Please use cable with a minimum of 0.5mm copper
core depending on the distance between system and radio
transmitter.
6.3.
Aux 12V
The X-
Series
Alarm Panel can supply 750mA of power to all bus-wired
peripherals, including keypads, expanders and remote receivers, etc.
6.4.
Siren
The siren connects directly to the siren output and can drive up to a 30 watt
siren.
Note: The siren must be self-driven, the siren output just supplies 12v DC and not an audio sound
and therefore you cannot use a "standard" speaker.
X-
SE
RIE