46
IDS X-Series Training v2.7
Location 211 to 218: Partition Configuration
Location Type: Bitmap
These options are to set how the system must behave when the partition needs to be armed.
LED Default Action
Description
1
OFF
Instant Arm
Instant arm allows the partition to arm without an exit delay.
2
ON
Instant Key-switch arm
When using a zone to arm or disarm this will enable the
partition to arm without an exit delay.
3
ON
Quick Arm Key
This is to enable/disable the pressing of the 1 key to start the
arm cycle instead of inserting a user code.
4
ON
Quick Stay Arm Key
This is to enable/disable the pressing of the 5 key to stay
arm.
5
ON
Auto Stay Arm if No Exit Zone is
Triggered
When arming with a user code and no entry/exit zone is
triggered then the partition will automatically arm in stay
mode.
6
OFF
Auto Stay Arm if No Exit Zone is
Triggered When Arming with a Key-switch
When arming using an arm/disarm zone and no entry/exit
zone is triggered then the partition will automatically arm in
stay mode.
7
OFF
Forced Arming
This will bypass any triggered zone allowing the system to
be armed even though there are triggered zones.
8
ON
Zone Bypassing
This enables or disables the ability for a user to bypass
zones using the 9 key.
9
OFF
Arm with Zones in the Entry Route
Violated
This allows movement to take place in a follower zone and
the entry/exit zone to be violated when you are about to arm.
10
OFF
Siren Toot on Arm
When the partition arms in the away mode the siren will give
one toot to indicate that it has armed.
11
OFF
Siren Toot on Disarm
When the partition disarms from being away armed it will toot
twice.
12
ON
Entry Beep
This will silence the keypad when the entry zone is triggered
to start the entry cycle.
13
ON
Exit Beep
This will silence the keypad when the partition starts to arm.
14
OFF
Engineer's Reset
This option will lock the partition, until the installer code has
been entered, when an alarm has occurred.
15
OFF
Auto Disarm
When enabled the partition will automatically disarm at the
time set in location 189.
16
OFF
Open & Close Reporting
This option will enable or disable opening & closing user
reporting events for this partition. All users are enabled by
default.
Exercise:
Let us enable siren toot on arm and disarm so the customer will know if the alarm is armed when
using a remote transmitter.
Instructions
Keypad presses
Enter the partitions location
[2][1][1] [*]
Option 10 and 11 need to be enabled
[1][0] [*] [1][1] [*]
Exit the location
[#]