The Voice Module is a plug-in board for the X-Series alarm panel. The board contains a DMTF decoder
chip and a flash memory chip which add telephonic voice interaction to the panel.
The user can receive alarm messages or can control the system via the phone by pressing keys on the
phone.
The user must enter their user code before any communication can take place. If the code is entered
incorrectly three times the system will hang up.
Note: The X-Series alarm panel must have firmware version 1.08 or higher and hardware version
“D” or higher.
1.
Hardware Installation
The voice module plugs onto the X-Series panel via the, 5 pin serial connector. When setup correctly a
message will be delivered to each telephone number entered into the system. The voice module also
allows a user to dial into the alarm system and control it via DTMF tones.
The controls are: Arm/Disarm, Bypass zones, Trigger an output, Query status of the partition
Note: The voice module only works on version “D” X-Series boards and firmware version 1.08