IDS X-Series Training v2.7 | Partition Options
45
Partition Options
The X-Series alarm panels have eight partitions that can have a number of zones and users allocated to
them. A partition is a separately controlled group of zones. Zones can be unique to the partition or can be
shared between partitions for areas that are common, and are referred to as common zone.
NOTE: A common zone will only trigger an alarm condition if all partitions that it’s allocated to are
armed.
Location 201 to 208: Placing Zones into a Partition
Location Type: Bitmap
By default only the first eight zones are placed into partition one and any added zones must be allocated to
a partition.
Valid Range: 01 - 64
Exercise: Zones 17 to 24 need to be programmed into partition 2.
Exercise: Zones 9 to 16 need to be programmed into partition 1.
Instructions
Key presses
To allocate all the zones that we configured earlier to partition 2
enter location 202.
[2][0][2] [*]
The green READY LED should be on and the ARM, AWAY and
POWER LEDs should be off.
Press the [*] key to move to the 2nd page.
[*]
This is a bitmapped location so data is entered by entering the
zone number of the zone you want to allocate to the partition.
[1] [*] [2] [*] [3] [*] [4] [*] [5] [*] [6] [*] [7]
[*] [8] [*]
Zone 1 to 8 LEDs should now be on.
Exit location 202.
[#]
Note: When using an LED keypad to gain access to zones 17 onwards press the [*] key to page to
the next sixteen zones.
The diagrams below show which page is being displayed via the keypad LEDs and which
zones they represent for the X64.
Curve keypad LEDs
Zones: 1 to 16 17 to 32 33 to 48 49 to 64
Classic keypad LEDs
Location
Partition
Default
Zones
Location
Partition
Default
Zones
Location
Partition
Default
Zones
201
1
1 to 8
204
4
207
7
202
2
205
5
208
8
203
3
206
6