IDS X-Series Training v2.7 | Event Reporting
69
Location 571 Global Split Reporting
Location Type: Bitmap
Location 572 Global Split Reporting
Location Type: Bitmap
LED Default
Action
Explanation
Split
Reporting
Option
Default
1
ON
AC Fail Reporting
After the wait time set in location 15, the AC failure
will be reported.
9
OFF
2
OFF
Communication Fail
Reporting
If the system cannot report a failure to report
message is sent.
10
OFF
3
ON
Telephone Line
Tamper Reporting
The alarm monitors the voltage on the telephone
line and if it goes missing a tamper is reported.
11
OFF
4
ON
Siren Fail Reporting
The siren output monitors the load on the output
and if it goes missing then a tamper is reported.
12
OFF
5
ON
Panel Low Battery Fail
Reporting
When the battery voltage drops to 10.5V a battery
low signal is sent, warning that the system is close
to shutting down.
13
OFF
6
ON
Enable Aux 12V Fuse
Fail Reporting
If a short circuit or too much current is drawn from
the auxiliary 12V the fuse will shut off and send a
signal warning of a problem.
14
OFF
7
OFF
Installer Reset
Required
If installer reset is enabled and the alarm is
triggered the system will not arm until the installer
code is entered. This alerts the security company of
this.
15
OFF
8
ON
Box Tamper
Reporting
The alarm has an input that monitors a switch that
monitors if the housing that it is in is opened.
16
OFF
LED Default
Action
Explanation
Split
Reporting
Option
Default
1
ON
Bus-wired Peripheral
Tamper Reporting
If any device connected on the keypad bus is
tampered with this option will send a report.
9
OFF
2
ON
Bus-wired Peripheral
Fail Reporting
If a device on the keypad bus fails and stops
communicating this report is sent.
10
OFF
3
OFF
Bus-wired Peripheral
Low Battery
Reporting *
If a device is powered by a battery because of a
power failure and the battery has reached a critical
level a low battery signal is sent.
11
OFF
4
ON
Wireless Detector
Battery Low
When a wireless device’s battery needs replacing a
battery low signal will be sent.
12
OFF
5
OFF
Wireless Detector
Supervision Fail
If a device stops communicating after a set amount
of time a supervision failure is sent
13
OFF
6
OFF
Wireless Receiver
Signal Jammed
When an unknown signal is detected that could
block signals from wireless detectors a jam is
reported.
14
OFF
7
OFF
Wireless Detector
RSSI Low
RSSI is the monitoring of signal strength from
detectors and if the signal drops below 20% a
message will be sent to alert the security company.
15
OFF
8
ON
AC Restored
After AC is restored a message can be sent.
16
OFF