Location 32: Auto Test Interval
Location Type: Standard
The time between test signals that are sent back to the monitoring company. Every time an auto test is
done the event is automatically and sequentially numbered, the counter starts at 0 and increments to 255.
Value Time Period
Value Time Period
Value Time Period
Value
Time Period
0
Every hour
6
Every 12 hours
11
Every 5 days
16
Every 10 days
1
Every 2 hours
7
Every 1 days
12
Every 6 days
17
Every 11 days
2
Every 3 hours
8
Every 2 days
13
Every 7 days
18
Every 12 days
3
Every 4 hours
9
Every 3 days
14
Every 8 days
19
Every 13 days
4
Every 6 hours
10
Every 4 days
15
Every 9 days
20
Every 14 days
5
Every 8 hours
Location 33: Auto Test Time
Location Type: Standard
This is the time of day that the test signal, set in location 32, must be transmitted.
Data Format: HHmm
Valid Range: 0000 - 2359
Default: 0010
Location 34: Download Code Default Disable
Location Type: Standard
The download code is a security code to stop any illegal connection and changing of data via external
connections, using IDSwift software. If this option is enabled then defaulting the system will have no effect
on the download code.
Valid Range: 0 or 10
Location 35: Hardware Default Switch Disable
Location Type: Standard
Every system has a hardware default switch which is activated by removing power from the system and
powering up while holding the switch down until the status LED flashes. If this option is enabled then the
only way to default is via the installer code and location 0.
Value
Action
0
Enable defaulting of the default button
10
Disable the defaulting of the default button
Value
Action
0
Enable Download code defaulting
10
Disable Download code defaulting
Status LED
Default Switch