IDS X-Series Training v2.7 | Triggering Outputs
65
Globally Triggered Outputs
Location Type: Extended
These events do not depend on a partition but are system related events. Each event can be programmed
to activate a PGM output.
Loc
Sub-
loc
Event
Description
Default
426
1
Wired Zone Expander Low Battery
Programmable Output
When a powered expander’s battery voltage drops below 11V
a low battery will be reported.
0000
2
Wired Zone Expander Battery
Restore Programmable Output
Once the battery is recharged a restore will be reported.
0000
3
Fire Sensor Power Programmable
Output
Fire sensors need to be reset when they have been triggered.
This option allows the system to reset the device.
00
4
Dual Reporting Programmable
Output
When the system has been set to dual reporting and the
second number is dialled, this option will trigger the output.
00
5
AC Fail on Smart Power Supply
Programmable Output
By default the Smart Power Supply monitors the 16V AC and
will trigger these outputs if there are any changes.
0000
6
AC Restore on Smart Power Supply
Programmable Output
0000
7
Low Battery on Smart Power Supply
Programmable Output
The battery is monitored constantly and will trigger these
outputs if the battery’s power becomes too low, or is
restored.
0000
8
Battery Restore on Smart Power
Supply Programmable Output
0000
Loc
Sub-
loc
Event
Description
Default
427
1
Fuse Fail on Smart Power Supply
Programmable Output
By default the Smart Power Supply monitors the fuse and will
trigger these outputs if there are any changes.
0000
2
Fuse Restore on Smart Power
Supply Programmable Output
0000
3
Event Log Output
Every time an event is written to the event log this will trigger
the action set.
0000
Configuring Pulse Length
The pulse duration of each PGM output can change to the required time in minutes and seconds, if needed.
Location 428: Onboard Outputs Pulse Length
Location Type: Extended
Each of the five onboard outputs can be lengthened or shortened.
[Installer Code] [*] [4] [2] [8] [*] [Output No.] [*] [m] [m] [s] [s] [*]
Data format: mmss
Valid Range: 0000 – 5959
Default: 0002
Location 429 to 434: Zone Expander Outputs Pulse Length
Location Type: Extended
Each of the six zone expanders has two outputs.
[Installer Code] [*] [Location] [*] [Output No.] [*] [m] [m] [s] [s] [*]
Data format: mmss
Valid Range: 0000 – 5959
Default: 0002