IDS X-Series Training v2.7 | Hardware
17
Xwave
2
LEDs
There are 4 LEDs on the Xwave
2
board marked:
Beacon: will flash when the Xwave
2
Hub is transmitting information.
Network: indicates the bi-directional networks information. The LED will be ON in
normal operation with no errors.
Trouble: indicates troubles with the Hubs connection to the X-Series bus. The LED
will be OFF if there are no troubles. If there are errors it will start pulsing the
error number.
Alert: will flash when the Xwave
2
Hub receives a message.
Xwave
2
Network pulse error number:
1.
Learn Mode
2.
Remote Panic
3.
Detector Low Battery
4.
Detector Tamper
5.
Supervision Loss
6.
Low Signal Strength
7.
Signal Jam
Xwave
2
Trouble pulse error number:
1.
Dead Keypad Bus
2.
Not Registered to Keypad Bus
3.
Registered but not receiving messages
4.
Invalid dipswitch
9.4.
Xwave
2
I/O Module
The Xwave2 I/O Module is a wireless solution that has two inputs that will supersede the wired zone the
module is taught to and the next consecutive zone. The output will automatically be registered and an
output number assigned to it depending on the zone that it is associated with.
(See Output programming)
LED Status
LED1 will light up when powering up and change state when a beacon from the Xwave
2
Hub is received.
2 Zone Inputs
12V Power Input
Programmable Output (Relay)