v
No:
There is still a problem. Contact your service provider.
v
Yes:
Go to step 13.
13.
If you changed the service processor or network settings, as instructed in previous procedures,
restore the settings to the value they had prior to servicing the system.
14.
If the indicator lights are still on, follow these steps:
a.
Select
Identify and Attention Indicators
from the Task Selection menu to turn off the system
attention and indicator lights and press Enter.
b.
Select
Set System Attention Indicator to NORMAL
and press Enter.
c.
Select
Set All Identify Indicators to NORMAL
and press Enter.
d.
Choose
Commit
.
Note:
This changes the system attention and identify indicators from the
Fault
state to the
Normal
state.
e.
Exit to the command line.
Verifying the installed part by using the HMC
If you have installed or replaced a part, use the Hardware Management Console (HMC) to update your
HMC records after you have completed a service action on your server. If you have reference codes,
symptoms, or location codes that you used during the service action, locate the records for use during
this procedure.
To verify the installed part, complete these steps:
1.
At the HMC, examine the service action event log for any open service action events. See “Viewing
serviceable events by using the HMC” on page 155 for details.
2.
Are there any service action events that are open?
No
: If the system attention LED is still on, use the HMC to turn off the LED. See “Activating and
deactivating LEDs by using the HMC” on page 155.
This ends the procedure.
Yes
: Continue with the next step.
3.
Record the list of open service action events.
4.
Examine the details of the open service action event. Is the error code associated with this service
action event the same as you gathered earlier.
v
No
: Select one of the following options:
– Review the other serviceable events, find one that does match, and continue with the next step.
– If the log does not match what you had gathered earlier, contact your service provider.
v
Yes
: Continue with the next step.
5.
Select and highlight the service action event from the Error Associated With This Serviceable Event
window.
6.
Click
Close Event
.
7.
Add comments for the serviceable event. Include any unique additional information. Click
OK
.
8.
Did you replace, add, or modify a field replaceable unit (FRU) of the open service action event?
v
No
: Select the
No FRU Replaced for this Serviceable Event
option, and click
OK
to close the
service action event.
v
Yes
: Perform the following steps:
a.
From the FRU list, select a FRU that you need to update.
b.
Double-click the FRU and update the FRU information.
c.
Click
OK
to close the service action event.
9.
If you continue to have problems, contact your service provider.
154
Disk drives or solid-state drives
Содержание 8248-L4T
Страница 1: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Страница 2: ......
Страница 3: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Страница 10: ...viii Disk drives or solid state drives...
Страница 18: ...2 Disk drives or solid state drives...
Страница 70: ...54 Disk drives or solid state drives...
Страница 90: ...74 Disk drives or solid state drives...
Страница 94: ...78 Disk drives or solid state drives...
Страница 98: ...82 Disk drives or solid state drives...
Страница 142: ...126 Disk drives or solid state drives...
Страница 144: ...128 Disk drives or solid state drives...
Страница 148: ...132 Disk drives or solid state drives...
Страница 158: ...142 Disk drives or solid state drives...
Страница 162: ...146 Disk drives or solid state drives...
Страница 198: ...182 Disk drives or solid state drives...
Страница 202: ...186 Disk drives or solid state drives...
Страница 212: ...196 Disk drives or solid state drives...
Страница 213: ......
Страница 214: ...Printed in USA...