a.
Select a drive in a parity set located in a load source capable slot, but is not the active load source
drive, and record the location of this drive.
b.
Select a non-configured drive of the same or larger capacity from either a non-load source slot or a
failed drive you are replacing with a non-configured drive.
6.
Stop the system if it is running. For instructions on stopping the system, see “Stopping a system or
logical partition” on page 143.
7.
Exchange the drives from the two locations you recorded in step 5 on page 106 by removing both
drives and placing them into the other drives slot.
8.
Start the system. See “Starting the system or logical partition” on page 139.
9.
Return to the procedure that sent you here and continue with the next step in that procedure.
Rebuilding data on a replacement disk drive or solid-state drive by
using IBM i
Learn how to rebuild data on replacement disks.
To rebuild data on the replacement drive, complete the following steps:
1.
If necessary, start System Service Tools (SST) by typing
strsst
on the command line of the IBM i
session and pressing Enter.
2.
Type your service tools user ID and service tools password on the Start Service Tools (STRSST) Sign
On display. Press Enter.
Note:
The service tools password is case sensitive.
3.
Select
Work with disk units
from the Start System Service Tools (SST) display. Press Enter.
4.
Select
Work with disk unit recovery
from the Work with Disk Units display. Press Enter.
5.
If you determined that the drive you replaced had
device parity protection (RAID)
, follow these
steps to restore device parity protection (RAID) on the drive:
a.
Select
Rebuild disk unit data
on the Work with Disk unit recovery display. Press Enter.
b.
Select
1
to rebuild the drive displayed (the drive displayed is the drive that you
removed
) on the
Rebuild Disk Unit Data display. Press Enter.
c.
Press Enter on the Confirm Rebuild Disk Unit Data display. The rebuild process might take several
minutes to complete.
d.
Press F5 to refresh the display until the
Percent complete
shows 5%.
e.
When the display shows at least 5% complete, you can either continue to monitor this display to
completion, or press F3 (Exit) to return to the Work with disk units display.
f.
Press F3 (Exit) to return to the System service tools display.
g.
Press F3 (Exit) to return to the Exit SST display and press Enter.
h.
Return to the procedure that sent you here.
6.
If the drive that you replaced had
mirrored protection
, follow these steps:
a.
Select
Replace configured unit
on the Work with Disk unit recovery display. Press Enter.
b.
Select the configured drive that you are exchanging (suspended drive) on the Select Configured
Unit to Replace display. Press Enter.
c.
Select the drive that you just installed on the Select Replacement Unit display. This drive has a
non-configured status.
Note:
In some cases, it might take several minutes for a new drive to display. Repeat these steps
until the new drive is shown.
Press Enter.
d.
Press Enter on the Confirm Replace of Configured Unit display to confirm your choice for
replacement.
Related tasks for disk drives or solid-state drives
107
Содержание 8248-L4T
Страница 1: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Страница 2: ......
Страница 3: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Страница 10: ...viii Disk drives or solid state drives...
Страница 18: ...2 Disk drives or solid state drives...
Страница 70: ...54 Disk drives or solid state drives...
Страница 90: ...74 Disk drives or solid state drives...
Страница 94: ...78 Disk drives or solid state drives...
Страница 98: ...82 Disk drives or solid state drives...
Страница 142: ...126 Disk drives or solid state drives...
Страница 144: ...128 Disk drives or solid state drives...
Страница 148: ...132 Disk drives or solid state drives...
Страница 158: ...142 Disk drives or solid state drives...
Страница 162: ...146 Disk drives or solid state drives...
Страница 198: ...182 Disk drives or solid state drives...
Страница 202: ...186 Disk drives or solid state drives...
Страница 212: ...196 Disk drives or solid state drives...
Страница 213: ......
Страница 214: ...Printed in USA...