This guide is available from the SCSI PCI Adapters web page.
If a hot-spare rebuild was not initiated by the controller, you need to initiate a rebuild on the newly
installed drive. To initiate the rebuild, follow these steps:
For an unprotected disk drive
If the drive you are replacing is in a RAID Level 0 disk array or in a failed RAID Level 5 or RAID Level
10 disk array, complete these tasks:
1.
Re-create the disk array.
2.
Re-create the file systems on the disk array.
3.
Copy the data back to the restored disk array from your backup media.
Rebuilding data by using the iprconfig command
If a hot-spare rebuild was not initiated by the controller, you must initiate a rebuild on the newly
installed drive. To initiate the rebuild, complete the following procedure using the iprconfig command.
For a disk drive in a RAID Level 5 or RAID Level 10 disk array
1.
Log in as root user.
2.
Type
iprconfig
on the command line of the Linux session and press Enter. The IBM Power RAID
Configuration Utility display is shown.
3.
Select
Work with disk unit recovery
from the IBM Power RAID Configuration Utility display. Press
Enter. The Work with Disk Unit Recovery display is shown.
4.
From the Work with Disk Unit Recovery display, select
Rebuild disk unit data
.
A Rebuild Disk Unit Data display similar to the following is shown.
5.
Type
1
(Rebuild) next to the disk drive you want to rebuild and press Enter.
Rebuild Disk Unit Data
Select the disks to be rebuilt
Type choice, press Enter.
1=Rebuild
OPT Name
PCI/SCSI Location
Description
Status
--- ------ -------------------------- ------------------------- -------------
1
0000:58:01.0.0/0:4:0
RAID
Array Member
Failed
e=Exit
q=Cancel
t=Toggle
Figure 71. Example Rebuild Disk Unit Data display
Related tasks for disk drives or solid-state drives
101
Содержание 8248-L4T
Страница 1: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Страница 2: ......
Страница 3: ...Power Systems Disk drives or solid state drives for the 8248 L4T 8408 E8D or 9109 RMD...
Страница 10: ...viii Disk drives or solid state drives...
Страница 18: ...2 Disk drives or solid state drives...
Страница 70: ...54 Disk drives or solid state drives...
Страница 90: ...74 Disk drives or solid state drives...
Страница 94: ...78 Disk drives or solid state drives...
Страница 98: ...82 Disk drives or solid state drives...
Страница 142: ...126 Disk drives or solid state drives...
Страница 144: ...128 Disk drives or solid state drives...
Страница 148: ...132 Disk drives or solid state drives...
Страница 158: ...142 Disk drives or solid state drives...
Страница 162: ...146 Disk drives or solid state drives...
Страница 198: ...182 Disk drives or solid state drives...
Страница 202: ...186 Disk drives or solid state drives...
Страница 212: ...196 Disk drives or solid state drives...
Страница 213: ......
Страница 214: ...Printed in USA...