15) Input the emergency stop, adjust it manually so it becomes the datum position for R Axis,
and insert the home-position adjusting tool (
φ
3). As shown in the figure below align the
position of either the D-cut surface on the R-axis tip or the D-cut surface on the hole for
insertion of the home-position adjustment tool (
φ
3).
Caution: Pay attention not to get the cables and pipes on the tool twisted.
16) With the home-position adjustment tool (
φ4
) being inserted, click “OK” in “Emergency stop
-> Positioning pin insertion” window.
Home-Position
Adjusting Tool (
φ
3)
D-cut Surface