Chapter 4 Home-Return /
Absolute Reset
82
4.3.1 Absolute Reset Preparation
Caution:
•
It is not necessary to have an absolute reset in ordinary case, however, make
sure to have the absolute reset conducted when an absolute error is occurred or
after dismantlement of the robot for a reason such as motor replacement.
Otherwise, it may cause a malfunction or critical operation error on the robot.
•
There may be a case that the indicated coordinates for
positioning
point cannot
be achieved before and after the absolute reset is conducted.
[Refer to “Scattered Positioning Points” in IXP SCARA Robot instruction]
1) Turn ON the power to the controller, and connect the PC software.
2) Make sure to have a backup of the parameters before conducting.
Select [Parameter]
→
[Edit] from the menu in the PC software to show the parameter edit
window. Press “Save As” button in the parameter edit window to save the parameters to
file data.
3) Select [Controller]
→
[Calibration Home/Abs. Encoder Reset] from the menu in the PC
software.