Chapter 7
Appendix
199
2) In case of category 2
24V
24V
Reset SW
Enable SW
Emergency Stop SW
G9SA-301
(OMRON)
G9SA-301
(OMRON)
Solenoid
Contactor
Solenoid Contactor
24V
24V
System I/O Connector
24V
24V
TP
9.EMGS1-
10.EMGS1+
7.EMGS2-
8.EMGS2+
12.EMGIN
3.ENBS1-
4.ENBS1+
1.ENBS2-
2.ENBS2+
6.ENBIN
11.EMGOUT
5.ENBOUT
VP24S
VP24S
12.EMGS1+_TP
9.EMGS1-_TP
5.EMGS2+_TP
6.EMGS2-_TP
24.ENBS1+_TP
23.ENBS1-_TP
22.ENBS2+_TP
25.ENBS2-_TP
ENBOK
MPO
MPI
24V
/SDWN
MSEL
ENB
EMG
Status
Detection
Motor
Driving
Circuit
Status
Detection
* Put the dummy plug (DP-4S) when a connection of the teaching pendant such as PC software