Chapter 4 Home-Return /
Absolute Reset
78
4.2 Absolute Reset Preparation (for Battery-less Absolute Type except for
SCARA Robot)
Caution :
It is not necessary to have an absolute reset in ordinary case, however, make
sure to have the absolute reset conducted when an absolute error is occurred or
after dismantlement of the robot for a reason such as motor replacement.
Otherwise, it may cause a malfunction or critical operation error on the robot.
1) Turn ON the power to the controller, and connect the PC software.
2) Make sure to have a backup of the parameters before conducting.
Select [Parameter]
→
[Edit] from the menu in the PC software to show the parameter edit
window. Press “Save As” button in the parameter edit window to save the parameters to
file data.
3) Select [Controller]
→
[Calibration Home/Abs. Encoder Reset] from the menu in the PC
software.
4) A warning window shows up. Check the content and click “OK”.